Your lab equipment is an investment. A UTM costs ₹5-25 lakh. A humidity chamber costs ₹2-8 lakh. An MFI tester costs ₹3-7 lakh. Together, a well-equipped plastic or rubber QC lab represents ₹20-80 lakh in capital. An Annual Maintenance Contract protects that investment the same way insurance protects a building – by preventing small problems from becoming expensive disasters. As a trusted AMC lab testing equipment India provider, Finetech built this exact protection into every contract – because insurance only works if someone is actually watching for the small failures before they become expensive ones.
Without an AMC, what happens is predictable: the UTM load cell drifts by 2% over a year and nobody notices until a NABL auditor flags it. The humidity chamber door gasket degrades and the RH reading drops 5% without any alarm. The MFI die gets clogged with degraded polymer and the next 50 MFI readings are 10-15% too high. These are not breakdowns – the machines keep running. But they are silently producing wrong data. And wrong data is worse than no data, because you make decisions based on it. This is exactly why laboratory equipment preventive maintenance India labs invest in exists – to catch drift and degradation while it is still cheap to fix.
The Finetech AMC is designed to catch these problems before they affect your test results. Our engineers perform scheduled preventive maintenance visits (2 per year standard), during which every critical parameter is inspected, calibrated, and documented. You receive calibration certificates for each instrument, a detailed inspection report, and a list of any parts that should be replaced before the next visit. For testing equipment maintenance contract India buyers comparing providers, this proactive inspection cycle is the difference between a real AMC and someone showing up once a year to look at the machines.
We service ALL brands, not just Finetech equipment. If your lab has a Finetech UTM, an imported humidity chamber, and an MFI tester from another Indian manufacturer, one Finetech AMC covers all three. One contract, one service provider, one point of contact for your entire lab.
| Service | Description | Frequency |
| Preventive maintenance visit | Comprehensive inspection, cleaning, lubrication, and functional check of all covered equipment | 2 visits per year (standard); quarterly visits available for high-usage labs |
| Calibration | Verification and adjustment of load cells, temperature sensors, timers, speed controllers, pressure gauges, and other measurement systems using traceable reference instruments | Every visit (included) |
| Calibration certificates | Traceable calibration certificates for each instrument – supporting NABL accreditation documentation | Issued at every visit |
| Inspection report | Detailed written report for each instrument: current condition, measurements taken, parts inspected, issues found, recommendations | Every visit |
| Electrical safety check | Inspection of wiring, earthing, contactors, fuses, and safety interlocks | Every visit |
| Wear part inspection | Inspection of grips, jaws, dies, door gaskets, seals, belts, and other wear components with replacement recommendations | Every visit |
| Software / firmware check | Verification of controller settings, software parameters, and sensor calibration constants | Every visit |
| Priority breakdown response | AMC customers receive priority scheduling for breakdown calls – phone diagnosis within 24 hours, on-site within 48 hours* | As needed |
| Technical phone support | Phone or WhatsApp consultation with our service engineer for troubleshooting, operating questions, or test method queries | Unlimited during AMC period |
| Item | Notes |
| Spare part replacement | Wear parts (grips, gaskets, seals, fuses, belts) identified during inspection are quoted separately. Parts are replaced only after your approval. |
| Damage from misuse | Damage caused by incorrect operation, voltage spikes, water damage, or unauthorised modifications |
| Consumables | Test dies, MFI die-cleaning tools, oil for hydraulic presses, silicone oil for HDT baths, reagents |
| Relocation | Moving equipment to a new location (quoted separately) |
| Major overhaul | Complete disassembly, refurbishment, or retrofit of old equipment (quoted as a separate project) |
Every AMC visit follows an equipment-specific checklist. Here is what our engineers inspect for the most common lab instruments. Whether you are researching an annual maintenance contract UTM India specifically or planning coverage for your whole lab, the checklist below is the same rigour we apply to every instrument.
Shore Hardness Tester / Muffle Furnace / HDT-VSP / Hot Water Bath / Other Equipment
Every Finetech product and every major brand of testing equipment has a documented AMC checklist. When you request an AMC quote, we will provide the specific checklist for each instrument in your lab.
| Scenario | Without AMC | With Finetech AMC |
| Calibration | Done ad-hoc when NABL audit approaches, or not at all | Scheduled every 6 months with traceable certificates |
| Load cell drift | Undetected for 12-18 months – all test results during that period are suspect | Caught and corrected every visit – data stays reliable |
| Door gasket failure (humidity chamber) | Discovered when RH readings become unstable – specimens not conditioned correctly | Inspected every visit – replacement recommended before failure |
| Breakdown response | Call the manufacturer, wait 5-10 days for a technician, lab is down | Priority response – phone diagnosis within 24 hours, on-site within 48 hours* |
| NABL audit preparation | Scramble to arrange calibration 2 weeks before the audit | Always audit-ready – certificates are current from the last AMC visit |
| Total cost over 3 years | Lower upfront, but higher total: emergency repairs + re-calibration + re-testing + rejected batches | Fixed annual cost, predictable budgeting, fewer surprises, lower total cost |
We provide AMC for all types of laboratory testing equipment, regardless of manufacturer:
| Equipment Category | Instruments Covered |
| Mechanical testing | Universal Testing Machine (UTM), Izod & Charpy Impact Tester, Dart Impact Tester, Shore Hardness Tester, Burst Strength Tester, Compression Set Apparatus |
| Thermal testing | MFI Tester, HDT/VSP Apparatus, Muffle Furnace, Hot Water Bath, Melting Point Apparatus |
| Environmental testing | Humidity Chamber, Vibration Tester, Drop Tester, ESCR Apparatus, Flammability Tester |
| Rubber-specific | DIN Abrasion Tester, Demattia Flex Tester, Ross Flex Tester, Pendulum Rebound, Vertical Rebound, Bennewart Flex Tester |
| Specimen preparation | Hydraulic Press, Pneumatic Press, Manual Press, Notch Cutter |
| Visual / optical | Colour Matching Cabinet |
| Other brands’ equipment | UTMs, impact testers, MFI testers, humidity chambers, and other lab equipment from ANY manufacturer – Indian or imported |
One AMC for your entire lab. Whether you have 3 instruments or 30, from 1 manufacturer or 5, we consolidate everything under one contract. One visit covers all your equipment. One invoice. One point of contact.
Manufacturer expertise, not just a calibration service. Finetech designs and builds testing equipment. Our engineers understand the machines from the inside out – the controller logic, the sensor behaviour, the mechanical tolerances. A third-party calibration technician checks if the reading is correct. Our engineer understands WHY it might be wrong and can fix the root cause.
All brands, one AMC. We service equipment from all manufacturers. Your lab has a mix of Finetech, imported, and other Indian equipment? One Finetech AMC covers everything. No more managing 3-5 separate service contracts.
Equipment-specific checklists, not generic visits. Every instrument has its own documented inspection checklist. Our engineers follow it item by item. Nothing is skipped, nothing is assumed.
Calibration certificates that support NABL accreditation. Every calibration we perform generates a traceable certificate. Your lab stays audit-ready year-round, not just before the NABL assessment. That is what calibration certificate lab equipment NABL India auditors expect to see attached to every instrument, every visit.
Fixed cost, predictable budgeting. One annual fee covers all scheduled visits, calibrations, and certificates. No surprise invoices, no ad-hoc charges for routine inspections.
Priority breakdown response. AMC customers go to the front of the queue. Phone diagnosis within 24 hours, on-site within 48 hours.* Our team frequently responds faster than these timelines.
All Equipments & specimen preparation products can be customised as per requirements.